Pull boxes shall be sized so that no cables in the box shall be tightly bent.
Never exceed the maximum pulling load rating.
362 24 bending radius 362 26 maximum total bends between pull points 360 362 28 trimmed to remove rough edges 362 30 support every 3 ft within 3 ft of any enclosure 362 48 joints between tubing fittings and boxes what about raceway fill.
Determining the size of underground pull and junction boxes to meet nec 314 16 code standards is required to prevent damage to conductor insulation.
Procedures for pulling fiber optic cable.
In many runs if the pulling distance is short enough and the pathway straight enough fiber optic cable can be pulled by hand without the use of special equipment.
Figure 4 figure 5.
Inspect the cable run to ensure there are no sharp bends or corners that exceed the minimum bend radius of the fiber.
Loops of cable commonly called service loops shall be provided at all intermediate pulling points such as in manholes and pull boxes.
On really long runs pull from the middle out to both ends.
Ansi tia 569 b 2004 commercial building standard for telecommunications pathways and spaces section 8 8 2 3 offers some guidance regarding cable fill in conduit.
Typically optical fiber cables do not carry electrical power but the metallic components of a conductive cable.
A length of free cable shall be provided at each end of a cable pull.
On long runs use proper lubricants and make sure they are compatible with the cable jacket.
Generally the minimum bending radius of a fiber cable under load is 20 d where d is the diameter of cable.
Always install listed optical fiber raceways per the following ent rules.
However first make sure the pull does not exceed the tensile loading limit established by the manufacturer for installation.
You should pull on the fiber cable strength members only.
The cables minimum bending radii shall not be violated.
And it promotes personal and site safety.
2 in many runs if the pulling distance is short enough and the pathway straight enough fiber optic cable can be pulled by hand without the use of special equipment.
At river crossings the distance between the bottom of the water and the drilling hole should be 10 times the diameter of the pipe and not less than 3 m 10 feet.
The cable should never be bent below its minimum bending radius.
Optical fiber cables are designed with a minimum bending radius.